Investigating the Performance of Solar Still System Integrated with and without Solar Trough Collector Using PCM Basin –An Experimental Study

Main Article Content

Hazim Jassim Jaber, Qais. A. Rishack, Qahtan. A. Abed

Abstract

The performance of two solar still systems has been investigated experimentally by taking the effect of parabolic trough collector (PTC) and phase change material (PCM). The effect was investigated under different environmental conditions. The productivity of the solar still was the main factor that was considered as a criterion for comparison. One day was taken under the investigation; 22-December 2020. Results show that a solar still using PTC with PCM has better productivity and temperature than without using PTC, And the additive PTC unit with the PCM basin causes an increase in temperatures of the system, and also an increase in rate productivity by 0.72 % than the solar still system without PTC.

Article Details

How to Cite
Hazim Jassim Jaber, Qais. A. Rishack, Qahtan. A. Abed. (2022). Investigating the Performance of Solar Still System Integrated with and without Solar Trough Collector Using PCM Basin –An Experimental Study. Annals of the Romanian Society for Cell Biology, 26(01), 3092–3102. Retrieved from https://annalsofrscb.ro/index.php/journal/article/view/11381
Section